failures and solutions XV Factory Suppliers Manufacturers Quotes

LED Control System LED Display Screen Solution Provider

failures and solutions XV

Color missing on LED Module

image.png

1. Signal cable not connect well (color missing a row of modules)
Solution: Check the signal cable connection and reconnect, also check the power supply for the first module in the row.
 
2. Module break down (color missing on single module)
Solution: Change module
 
3. Module break down or flat cable not connect well (color missing on part of the module)
Solution: Change the module or reconnect the flat cable.